Annual Inspection Technician Checklist
1. Conduct Visual Inspection
1. ☐ Inspect the system for visible damage, including the pressuriser and hoses.
2. ☐ Check the filter condition and replace if required.
3. ☐ Confirm whether the HEPA filter requires annual replacement.
4. ☐ Inspect the sensor tube and sensor filter; replace as required.
2. Perform Pre-Cleaner Maintenance
1. ☐ Remove and dismantle the Donaldson pre-cleaner.
2. ☐ Inspect the vacuator valve and replace if required.
3. ☐ Clean the pre-cleaner thoroughly as needed.
4. ☐ Reassemble the pre-cleaner correctly.
3. Inspect Cabin Integrity
1. ☐ Inspect the machine cabin, including all door and window seals.
2. ☐ Repair or replace damaged or ineffective seals.
4. Perform Pressure Test
1. ☐ Confirm all cabin doors are closed.
2. ☐ Start the machine.
3. ☐ Switch off the machine HVAC system before testing.
4. ☐ Run the pressure test in the Cleancab application from the commissioning or management page.
5. ☐ Record the maximum pressure achieved.
6. ☐ Reset the pressure test icon.
7. ☐ Allow the system to stabilise at the target pressure.
8. ☐ If fan speed exceeds 80% to reach target pressure, complete a cabin sealing test and carry out repairs.
9. ☐ Confirm pressuriser fan speed is within the recommended 20% to 70% range.
10. ☐ Do not operate the HVAC system while testing pressuriser fan speed.
5. Complete Calibration
1. ☐ Complete system calibration in accordance with the approved calibration procedure.
6. Conduct CO₂ Gain Test
1. ☐ Confirm the system has been calibrated and stabilised.
2. ☐ Perform the CO₂ gain test in accordance with the approved CO₂ gain procedure.
7. Manage System Data
1. ☐ Save the fault code list from filter history for future reference.
2. ☐ Clear fault codes in the Cleancab management section.
3. ☐ Save filter history before clearing it, if clearing is required.
4. ☐ Do not clear running logs unless the unit is being installed on a new machine.
8. Complete Reporting Requirements
1. ☐ Create and export the inspection report from the report section in the Cleancab menu.
☐ Include customer details and the recorded test pressure level in the final report.
Replacement Parts - Annual Recommendation
1. ☐ HEPA filter - Part number H14MP36526597-kit
2. ☐ Vacuator valve - Part number P112803
3. ☐ Sensor filter - Part number UC5M